Lease vs PPA vs cash purchase for commercial solar in 2026
The ITC is gone for new starts. The financing decision that was straightforward in 2024 is not straightforward in 2026. A working framework for cash, PPA, lease, C-PACE, and elective pay.
A 300 kW ground-mount system on a Front Range warehouse pencils out very differently depending on which column you put it in: capital expenditure, operating lease, or off-balance-sheet PPA. Before July 4, 2026, the gap between those columns was manageable because the 30 percent ITC reduced every option. Now that the ITC window has closed for new projects, the financing structure does more to determine whether a deal works than almost any other variable.
The structural shift is this: the ITC still exists, but only for the entity that owns the system at placed-in-service date. For a project placed in service by December 31, 2027, a PPA or lease developer can still claim 30 percent. A business buying the same system outright cannot, unless it established beginning of construction before July 4. That asymmetry is reshaping what developers are willing to quote and what financing structures make sense for which buyers.
100 percent bonus depreciation under MACRS remains in place, permanently restored by the OBBBA. For a C-corp with active federal tax liability, year-one depreciation on a $1 million system produces $175,000 to $250,000 in tax savings depending on effective rate. That still materially reduces net project cost without the ITC, but it requires ownership, which requires capital or a lender.
Cash purchase: who it works for now
A cash purchase gives the owner the full stack: system ownership, all energy production, MACRS depreciation, and any remaining state credits. For a Front Range owner with consistent federal tax liability and capital to deploy, it produces the best 20-year return. The payback math is just harder than it was six months ago.
A 300 kW DC rooftop at $2.50 to $2.80 per watt lands at $800,000 as a working baseline. Without the ITC, the full $800,000 is depreciable. At a 25 percent effective rate, year-one bonus depreciation yields $200,000 in tax savings. Net effective cost: approximately $600,000.
A 300 kW system on the Front Range generates approximately 435,000 kWh per year (1,450 kWh/kW-DC, NREL PVWatts). Against Xcel commercial rates of $0.12 to $0.15 per kWh, annual savings run $52,000 to $65,000. Simple payback on $600,000 net cost at $58,000 average savings: approximately 10.3 years. With the ITC, it would have been approximately 6.5 years. The 3.8-year difference is the cost of missing the BOC deadline.
Where cash purchase loses ground: The bonus depreciation benefit only materializes if you have the federal tax liability to absorb it. Pass-through entities in a lean year, nonprofits, and municipalities get no value from MACRS. For those entities, cash is the most expensive structure in the post-ITC environment.
Commercial solar loans: preserving ownership without the capital outlay
A financed purchase gives the owner the same tax position as a cash purchase, with the added cost of debt service. Commercial solar loan terms in mid-2026 run 7 to 12 years at 6 to 9 percent APR. On an $800,000 project financed at 7.5 percent over 10 years, monthly debt service is approximately $9,500, or $114,000 annually. Annual bill savings of $58,000 mean the system runs at a pre-tax cash deficit of roughly $56,000 per year.
The year-one depreciation benefit ($200,000 in tax savings at 25 percent rate) turns the first-year combined position positive by $144,000. After year one, the ongoing position is electricity savings only against debt service, serviceable but not self-funding until utility rates escalate enough to close the gap. The depreciation capture is what makes the financed structure work, which means a business in a lean tax year gets less out of it.
Operating leases: who still offers them and what they cost
An operating lease places the system on the property owner's roof with the developer as legal owner. The property owner pays a fixed monthly lease payment, claims no ITC or depreciation, and receives the electricity benefit through bill reduction or net metering credit.
The ITC flows to the third-party owner, who prices the lease to reflect their cost of capital net of the credit. A project placed in service by December 31, 2027 allows the developer to claim 30 percent. That is the structural reason lease and PPA economics have held up while cash purchase economics have thinned. Section 6418 transferability, intact under the OBBBA, gives developers a second path to monetize the ITC by selling it to a corporate buyer, enabling more competitive pricing.
Leases run 15 to 20 years. The lessee pays for equipment availability, not kilowatt-hours produced. If the system underperforms, the payment is still due. For owners who want production-linked savings, a PPA is the closer match.
For entities that cannot use tax credits, leases and PPAs are structurally the correct choice. The developer absorbs the tax complexity; the property owner gets the energy savings.
One constraint: the commercial lease market for sub-$1M projects is thinner than residential. Fewer providers underwrite behind-the-meter commercial transactions, and projects compete for tax equity capacity that tightened post-OBBBA. A 250 kW rooftop on a single-tenant industrial building with a creditworthy tenant is viable. A 75 kW system on a multi-tenant retail strip may not find competitive third-party terms.
PPAs: the 25-year math that most proposals leave out
A power purchase agreement is a contract under which a third-party developer installs and owns a system on your property and sells you the electricity at a per-kilowatt-hour rate below your current utility bill. Commercial PPA terms in 2026 run 15 to 25 years, with 20 years as the most common.
Front Range behind-the-meter PPA rates are currently quoting $0.09 to $0.14 per kWh at commencement, depending on system size, credit quality, and domestic content premiums. Against Xcel commercial rates of $0.12 to $0.15 per kWh, the savings at the headline rate are real but not dramatic.
The number most proposals omit is the 20-year compounded cost. An escalating PPA at $0.10 per kWh with a 2 percent annual escalator reaches $0.122 by year 10 and $0.135 by year 15. Aggregate PPA payments over 20 years: approximately $1.06 million on a 300 kW system (435,000 kWh annually). Cash ownership over the same period, after $600,000 net effective cost and $1.16 million in gross savings at flat rates, produces roughly $560,000 in cumulative net savings. The PPA delivers that electricity for $1.06 million. The gap is the price of zero capital outlay and zero operational risk.
For a CFO whose cost of capital exceeds the solar return, the PPA makes financial sense. For a CFO with active federal tax liability and a 15-plus-year hold, ownership typically wins. The break-even discount rate is generally 7 to 10 percent depending on rate escalation assumptions.
The operational transfer that matters: Under a PPA, equipment risk stays with the developer. Two inverter replacements over 25 years ($15,000 to $40,000 each) shift $30,000 to $80,000 in maintenance cost to the developer. For an owner who does not want facilities staff managing solar equipment, that transfer has real value even when the per-kWh comparison slightly favors ownership.
C-PACE: the Colorado-specific structure worth running seriously
Colorado's C-PACE program, administered by the Colorado New Energy Improvement District, allows commercial property owners to finance up to 100 percent of a solar installation through a long-term property tax assessment. The assessment runs up to 25 years, carries a fixed interest rate, and transfers to the buyer if the property sells.
Current C-PACE rates for Colorado commercial solar run 6 to 9 percent, with 20 to 25 year terms. Repayment is through the property tax bill in biannual installments. The property owner retains system ownership, so depreciation flows through identically to a cash purchase. C-PACE does not restore the ITC for projects that missed the July 4, 2026 BOC deadline. It is a financing mechanism, not an incentive.
Where C-PACE wins: On a 300 kW system at $800,000 financed at 7 percent over 20 years, annual assessment payments run approximately $75,000 ($6,250 per month). Annual electricity savings at $0.13 per kWh against 435,000 kWh production run approximately $56,550 ($4,700 per month). Pre-tax, the project runs at an $18,450 annual negative before depreciation. Year-one depreciation ($200,000 in tax savings) makes the combined first-year position strongly positive. Years two through roughly six run at a modest annual negative before utility rate escalation closes the gap. Xcel's pending 9.9 percent increase, if approved in August 2026, would bring annual savings to approximately $62,000, narrowing the gap to roughly $13,000. Full coverage requires modest utility escalation, which is the base case given Xcel's trajectory but not a guarantee.
Where C-PACE hits limits: CPACE requires lender consent if a mortgage is in place. Properties with CMBS financing, ground leases, or complex partnership structures often face eligibility hurdles. Start the lender consent conversation before submitting the application; response times run 30 to 90 days. Tenants cannot initiate C-PACE at all.
Tax-exempt entities: elective pay still runs after the OBBBA
Nonprofits, municipalities, and school districts generate no federal tax liability, so the ITC is worthless to them as a direct credit. The IRA's elective pay provision changed that by allowing qualifying tax-exempt entities to receive a direct cash payment from the IRS equal to the value of the credit.
The OBBBA did not eliminate elective pay for tax-exempt entities. It remains active. One requirement many advisors undersell: IRS pre-registration must be completed before the system is placed in service. A nonprofit that completes construction but skips pre-registration forfeits elective pay for that tax year. A qualifying nonprofit with a project placed in service by December 31, 2027 can receive a direct payment equal to 30 percent of installed cost. The payment steps down to 22.5 percent in 2033 and 15 percent in 2034. Domestic content requirements apply; a project seeking the full 30 percent must meet FEOC compliance standards.
For a Colorado nonprofit installing a 100 kW system at $280,000, elective pay produces an $84,000 direct IRS payment. That turns a structure with no federal recovery into one where the nonprofit owns the system and gets 30 percent back. Administrative requirements: an EIN, IRS pre-registration before placed-in-service, and Form 990-T with Forms 3468 and 3800. The dollar value justifies the process on any system above 25 kW.
The decision framework: which structure wins for which entity
There is no single correct answer across entity types. The table below summarizes where each structure delivers its best result in the post-July 4 environment.
System size matters, and the table does not show it. PPA economics improve with scale; smaller systems attract fewer competitive providers and carry higher per-kWh rates. For a 50 kW rooftop, the gap between a PPA at $0.13 per kWh and a C-PACE-financed cash purchase with full depreciation is wide enough that ownership is clearly superior for a tax-paying entity, even without the ITC. Commercial accounts on Xcel general service tariffs also carry demand charge components that add to bill savings beyond the per-kWh calculation.
Colorado-specific factors: Xcel rates, community solar, and the Enterprise Zone
Two variables specific to Colorado commercial solar merit direct attention in any financing decision.
Xcel rate trajectory: Xcel's pending Proceeding 25AL-0494E, seeking $356 million in new annual electric revenue at approximately 9.9 percent on average bills, targets an August 2026 effective date. That increase improves ownership payback math and reduces the attractiveness of a fixed-rate PPA. A PPA signed today at $0.10 per kWh starts looking comparatively worse if the approved Xcel rate jumps to $0.137 per kWh in August. The rate case is not a reason to delay, but it is a reason to negotiate PPA rates before the new schedule takes effect.
Enterprise Zone Corporate Tax Credit: Colorado Enterprise Zone businesses can claim a 3 percent state income tax credit on qualifying renewable energy investments, up to $750,000 per tax year, stacking on top of federal treatment. For a cash or C-PACE project in an Enterprise Zone, the credit shortens payback by 0.5 to 1 year. Confirm eligibility with a Colorado tax advisor before committing.
Community solar: For property owners who lease their building or face structural or interconnection limits, Xcel Solar*Rewards community solar subscriptions provide a bill credit of 5 to 15 percent on subscribed generation with no capital outlay. Not a substitute for an owned system, but the available path for tenants who cannot install on-site.
What a responsible developer should show you
Any reputable developer should run four things before you choose a structure.
First, a 25-year LCOE comparison across all options. A PPA at $0.10 per kWh with a 2 percent escalator has a materially different lifetime cost than cash ownership at approximately $0.056 per kWh for a fully-depreciated Front Range system. The year-one rate is not the decision variable.
Second, NPV modeled against your actual tax position. Depreciation value varies by effective rate. A post-ITC cash purchase with a 10-year payback typically delivers an unlevered IRR of 9 to 12 percent on the savings stream alone.
Third, an ITC access audit. For any project that might still qualify under the December 31, 2027 placed-in-service window, confirm the developer has active tax equity capacity. Without it, a PPA or lease cannot price in the credit.
Fourth, Xcel rate escalation sensitivity. For a 20-year PPA, the difference between 3 percent and 1 percent annual utility escalation moves the NPV of the ownership alternative by $80,000 to $150,000 on a 300 kW project. Any model that omits it is incomplete.
Solara Pro is a commercial-only solar developer based in Broomfield, Colorado. Financing rates and program terms cited above reflect the market as of July 2026 and change frequently. Every commercial solar transaction should be reviewed by qualified tax and legal counsel before signing.